# The Acetylene Safety (England and Wales and Scotland) Regulations 2014, Paragraph 3: Further requirements for an acetylene manifold


An acetylene manifold may only be used if it is—
(a) designed to prevent the mixture of air, or oxygen, with acetylene gas within the acetylene manifold;
(b) fitted with rigid pipework with an internal diameter equal to or less than 25mm;
(c) fitted with a flexible hose where rigid pipework is not practicable and the flexible hose—
(i) is kept at the minimum practicable length; and
(ii) has an internal diameter equal to or less than 25mm; and
(d) not subjected to pressure greater than that within any attached cylinder.

---