# The Aerosol Dispensers Regulations 2009, Paragraph 6.3.1.3.1.4


Each aerosol dispenser is to be tested:
(a) when full according to the complete procedure, with the gas burner in the range of 15-90cm distance from the actuator of the aerosol can;
(b) when 10-12% full nominal (% by mass) only one test, either at 15cm distance from the actuator when the spray from a full can did not ignite at all, or at the flame ignition distance of the spray of a full can plus 15cm.

---
Source: https://www.legislation.gov.uk/uksi/2009/2824/schedule/1A/paragraph/6.3.1.3.1.4 (the official version)