{
  "url": "https://openlegislation.uk/aerosol-dispensers-regulations-2009/schedule-1A/paragraph-6.3.2.2.2.1",
  "json_url": "https://openlegislation.uk/aerosol-dispensers-regulations-2009/schedule-1A/paragraph-6.3.2.2.2.1.json",
  "legislation": "uksi/2009/2824",
  "legislation_title": "The Aerosol Dispensers Regulations 2009",
  "legislation_url": "https://openlegislation.uk/aerosol-dispensers-regulations-2009",
  "path": "schedule/1A/paragraph/6.3.2.2.2.1",
  "kind": "paragraph",
  "number": "6.3.2.2.2.1",
  "heading": null,
  "text": "A cylindrical vessel approximately 200 dm3 volume, approximately 600mm in diameter and approximately 720mm long and open at one end shall be modified as follows:\n(a) a closure system consisting of a hinged cover shall be matched to the open end of the receptacle; or\n(b) a plastic film 0.01 to 0.02 mm thick may be used as a closure system; if the test is carried out with a plastic film this must be used as described below: stretch the film over the open end of the drum and hold it in place with an elastic band; the strength of the band shall be such that when placed around the drum resting on its side, it stretches by only 25mm when a mass of 0.45 kg is attached to its lowest point; cut a 25 mm slit in the film, starting 50 mm from the edge of the drum. Ensure that the film is taut;\n(c) at the other end of the drum drill a 50mm diameter hole 100mm from the edge in such a way that the orifice is uppermost when the receptacle is laid down and ready for the test (Figure below);\n(d) on a 200 × 200 mm metal support place a paraffin wax candle 20 to 40 mm in diameter and 100 mm high; the candle shall be replaced when having a height of less than 80 mm; the candle's flame is protected from the action of the spray by a 150 mm wide, 200 mm high deflector; this includes the plane inclined at 45° produced 150 mm from the base of the deflector (see Figure below);\n(e) the candle placed on the metal support shall be positioned midway between the two ends of the drum (see Figure below);\n(f) the drum is laid on the ground or on a support at a spot where the temperature is between 15 °C and 25 °C; the product to be tested will be sprayed within the drum of roughly 200 dm3 in which there will be a source of ignition.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Sch. 1A inserted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 13 para. 8 (with reg. 2 as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2009/2824/schedule/1A/paragraph/6.3.2.2.2.1",
    "retrieved_at": "2026-10-29T03:03:51.158826+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}