Reference method
Sampling and analysis of benzeneA pumped sampling method on a sorbent cartridge followed by gas chromatographic determination
Analysis of carbon monoxideA non-dispersive infra-red spectrometric (NDIR) method
Sampling of leadThe same reference method as for PM10
Analysis of leadISO 9855: 1993 Ambient air — Determination of the particulate lead content of aerosols collected in filters. Atomic absorption spectroscopy method
Analysis of nitrogen dioxide and oxides of nitrogenISO 7996: 1985 Ambient air — determination of the mass concentrations of nitrogen oxides — chemiluminescence method
Sampling and measurement of PM10The reference method for the sampling and measurement of PM10 is that described in EN 12341 “Air Quality — Field Test Procedure to Demonstrate Reference Equivalence of Sampling Methods for the PM10 fraction of particulate matter” . The measurement principle is based on the collection on a filter of the PM10 fraction of ambient particulate matter and the gravimetric mass determination
Analysis of sulphur dioxideISO/FDIS 10498 (Standard in draft) Ambient air — determination of sulphur dioxide — ultraviolet fluorescence method