OpenLegislation

Regulation 5 Approved measuring devices – underlying level of noise

Original text. Later amendments are not shown.

(1)

For the purposes of section 49(1) of the Act (approval of measuring devices), subject to paragraph (2), sound level meters which:

(a)

comply with the requirements of Class 1 of BS EN 61672; and

(b)

are capable of determining the A-weighted sound pressure level using time-weighting ‘F’,

are devices approved for the measurement of the underlying level of noise, when used in accordance with the requirements of regulations 7 and 8.

(2)

Where LAN,T measurements are used to determine the underlying level of noise, the devices specified in paragraph (1) must in addition:

(a)

sample the sound pressure level at a rate of not less than 10 times per second; and

(b)

use in the statistical calculation a class interval of no greater than 0.5 decibels.

(3)

When time weighting ‘F’ is used for the purposes of paragraph (1) it shall not exceed 0.6 seconds in a period of no shorter than one minute and no longer than 5 minutes.