# The Blood Safety and Quality Regulations 2005, Paragraph 2.3


For autologous donations, the measures marked with an asterisk (*) are recommendations only.
Component
Quality measures required
Acceptable results for quality measures
The required frequency of sampling for all measurements shall be determined using statistical process control
Red cells
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 45g per unit
Haemolysis
Less than 0.8% of red cell mass at end of the shelf life
Red cells, buffy coat removed
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 43 g per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Red cells, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40g per unit
Leucocyte content
Less than 1 x 106 per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Red cells, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 45g per unit
Haemolysis
Less than 0.8% of red cell mass at end of the shelf life
Red cells, buffy coat removed, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 43g per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Red cells, leucocyte-depleted, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40g per unit
Leucocyte content
Less than 1 x 106 per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Red cells, apheresis
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40g per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Whole blood
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis 450ml +/- 50ml
For paediatric autologous whole blood collections – not to exceed 10.5ml per kg body weight
Haemoglobin (*)
Not less than 45g per unit
Haemolysis
Less than 0.8% of red cell mass at the end of the shelf life
Platelets, apheresis
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single donation are permitted within the limits that comply with validated preparation and preservation conditions
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Platelets, apheresis, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single donation are permitted within the limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 1 x 106 per unit
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Platelets, recovered, pooled
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 0.2 x 109 per single unit (platelet-rich plasma method)
Less than 0.05 x 109 per single unit (buffy coat method)
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Platelets, recovered, pooled, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 1 x 106 per pool
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Platelets, recovered, single unit
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 0.2 x 109 per single unit (platelet-rich plasma method)
Less than 0.05 x 109 per single unit (buffy coat method)
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Platelets, recovered, single unit, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 1 x 106 per unit
pH
Minimum 6.4 corrected for 22°C, at the end of the shelf life
Plasma, fresh-frozen
Volume
Stated volume +/- 10%
Factor VIIIc(*)
Average (after freezing and thawing): 70% or more of the value of the freshly collected plasma unit
Total protein
Not less than 50g/l
Residual cellular content(*)
Red cells: less than 6.0 x 109/l
Leucocytes: less than 0.1 x 109/l
Platelets: less than 50 x 109/l
Plasma, fresh-frozen, cryoprecipitate-depleted
Volume
Stated volume +/-10%
Residual cellular content(*)
Red cells: less than 6.0 x 109/l
Leucocytes: less than 0.1 x 109/l
Platelets: less than 50 x 109/l
Cryoprecipitate
Fribrinogen content(*)
Greater than or equal to 140mg per unit
Fractor VIIIc content (*)
Greater than or equal to 70 international units per unit
Granulocytes, apheresis
Volume
Less than 500ml
Granulocyte content
Greater than 1 x 1010 granulocytes per unit

---
Source: https://www.legislation.gov.uk/uksi/2005/50/schedule/part/5/paragraph/2n15 (the official version)
Page: https://openlegislation.uk/blood-safety-and-quality-regulations-2005/schedule/part-5/paragraph-2n15
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.