OpenLegislation

Schedule TABLE TO BE SUBSTITUTED FOR TABLE IN SCHEDULE 1 TO THE PRINCIPAL REGULATIONS

Original text. Later amendments are not shown.

“

TABLE OF PARTICULARS

Buildings to which applicableParticulars
All buildings.
1

The level of (a) site of the building, (b) lowest floor, (c) adjacent ground (including any road) in relation to one another and some known datum.

2

The position, materials and dimensions of (a) foundations, (b) walls, (c) windows including opening area and direction of openings, (d) doors showing direction of opening (e) floors, (f) roofs, (g) chimneys and flues, (h) ventilators and ventilation ducts (i) stairways, landings and balconies (j) other parts of the building whether above or below ground level.

3

Details of construction and in particular details of any framework and size and position of reinforcing material.

4

Details of calculation of loading and strength.

5

Indication of compartment floors and compartment walls and separating floors and separating walls and details of fire stopping.

6

Position, materials and dimensions (and weight) of any damp-proof course or other moisture barrier.

7

Position of any wash basin, shower bath, bath tub or sitz bath, kitchen sink or other built-in equipment or sanitary appliance for which standards are prescribed in the building standards regulations as read with the Technical Standards. The dimensions of any wash basin must also be shown.

8

Position, materials, dimensions and form of any soil, soil-waste, waste or rain water and ventilating pipes.

9

Position, materials, line, depth, inclination and dimensions of every drain and means of ventilation thereof and the relationship and level to any sewer, sewage treatment works or other outlet into which drains are to discharge (the scale of this drawing may be to a smaller scale than 1:100 at the discretion of the local authority).

10

Position, form and dimensions of traps, manholes and access openings.

11

Such particulars as are necessary to show that the operations involved will be conducted in accordance with the building operations regulations.

Buildings referred to in specifications E3.16 and Q2.17 of the Technical Standards.
12

The position and dimensions of teh lift well, the lift car and machine room.

Buildings to which regulation 13 of the building standards regulations and Part E of the Technical Standards apply.
13
(a)

The escape routes available as a means of escape from fire and their dimensions.

(b)

The position of ground hydrants required by the building standards regulations as read with specification E3.2 of the Technical Standards.

Buildings to which regulation 29(2) of the building standards regulations and specification Q2.10 of the Technical Standards apply.
14

The number of socket outlets and the rooms in which they are or are to be fitted.

”