Regulation 2 Amendment of Building Standards (Scotland) Regulations 1990
The Building Standards (Scotland) Regulations 1990f1 shall be amended in accordance with the following paragraphs.
In paragraph (1) of regulation 2 (interpretation)–
for the definition of “compartment” there shall be substituted:–
““compartment”, except in the expression “watercloset compartment”, means a part of a building (which may contain one or more rooms, spaces or storeys and includes, where relevant, the space above the top storey of the compartment) constructed so as to prevent the spread of fire to or from another part of the same building; and “compartmented” and “compartmentation” shall be construed accordingly;”;
for the definitions of “compartment floor” and “compartment wall” there shall be substituted:–
““compartment floor” and “compartment wall” mean respectively a fire resistant floor and a fire resistant wall used in the separation of one compartment from another;”;
for the definition of “gallery” there shall be substituted:–
““gallery” means a raised floor or platform, including a raised storage floor, which is open to the room or space into which it projects and which–
- (a)
has every part of its upper surface not less than 1.8 metres above the surface of the main floor of the said room or space; and
- (b)
occupies (or, in the cases of there being more than one gallery, together occupy) not more than one-half of the floor area of the said room or space;”;
for the definition of “storey” there shall be substituted:–
““storey” means that part of a building which is situated between the top of any floor being the lowest floor level within the storey and the top of the floor next above it being the highest floor level within the storey or, if there is no floor above it, between the top of the floor and the ceiling above it or, if there is no ceiling above it, the internal surface of the roof; and for this purpose a gallery or catwalk, or an openwork floor or storage racking, shall be considered to be part of the storey in which it is situated;”; and
for the definition of “Technical Standards”f2 there shall be substituted:–
““Technical Standards” means the Technical Standards for compliance with the Building Standards (Scotland) Regulations 1990 issued by the Scottish Office in October 1990, as amended by the substitute pages issued by the Scottish Office in and dated July 1993f3, June 1994f4, November 1996f5 and December 1997;”.
In paragraph (2) of regulation 22 (conservation of fuel and power)–
sub-paragraph (a)(iii) shall be deleted and there shall be substituted therefor–
“(iii)are unheated or have a space heating system which is designed to give a maximum output not exceeding–
(a)for buildings of purpose groups 2 to 5, 25 watts per square metre of floor area, and
(b)for buildings of purpose groups 6 and 7, 50 watts per square metre of floor area;”.
in sub-paragraph (d)–
after the word “conservatories”, there shall be inserted the words “which are unheated,”, and
the words “and which have external access” shall be deleted; and
sub-paragraph (e) shall be deleted.
In regulation 23 (ventilation of buildings) paragraphs (2) and (4) shall be deleted.
In Schedule 1 (exempted classes of buildings) in class 8, delete the exception in column (3) and substitute therefor–
“A septic tank, or private sewerage treatment works, which is serving a building subject to regulation 24.”.
In Schedule 2 (fixtures not requiring a warrant), in category 10, in column (2) add at the end “on a straight flight of stairs”.
Annotations
Footnotes
- f1
-
S.I. 1990/2179, amended by S.I. 1993/1457, 1994/1266 and 1996/2251.
- f2
-
Substituted by S.I. 1996/2251.
- f3
-
These amendments to the Technical Standards were given effect to by S.I. 1993/1457.
- f4
-
These amendments to the Technical Standards were given effect to by S.I. 1994/1266.
- f5
-
These amendments to the Technical Standards were given effect to by S.I. 1996/2251.