(1) Item
(2) Maximum design parameter
Finished ground level (+ or – 0.5m)
9m AOD
Configuration of individual final settlement tanks
8 No. circular tanks each with a 39m diameter
Depth
4m AOD (5m below FGL)
Foundations
Piles to a depth of -16m AOD (25m below FGL)
Height
18m AOD (9m above FGL)
Return activated sludge/surplus activated sludge pumps
18 No.
Overall footprint of final settlement tanks including combined return activated sludge/surplus activated sludge pumping station
130m x 225m

---