Paragraph 1
For the purposes of Part I of this Schedule, preparations which comply with the following conditions shall not be required to be classified as flammable, namely:—
the preparation is not classified as toxic or corrosive;
the preparation is a solution or homogeneous mixture which does not contain nitro-cellulose;
the flash point of the preparation is equal to or greater than 21°C;
in a suitable solvent separation test, the solvent which separates is not more than 3 per cent. of the volume of the preparation; and
the viscosity of the preparation when determined at 23°C in a flow cup conforming to the International Standards Organisation Standard ISO 2431—1984 or British Standard BS3900: Part A6—1986 and having a jet diameter of 6mm is—
in a case where the preparation contains not more than 60 per cent. of a flammable liquid with a flash point of 55°C or less, not less than 40 seconds, or
in any other case, not less than 60 seconds.