# The Control of Electromagnetic Fields at Work Regulations 2016, Paragraph 5: Notes

Extent: E+W+S

From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where “f” is the frequency in GHz).
Table AL4 – AL for exposure to electromagnetic fields from 10 to 110MHz
Frequency range
Limb current AL (IL) [mA]
10 ≤ f ≤ 110 MHz
100
Exposure levels not exceeding the ALs will be compliant with:
The health effect ELV in Table ELV4 - localised SAR in the limbs

---
Source: https://www.legislation.gov.uk/uksi/2016/588/schedule/part/2/chapter/2/paragraph/5 (the official version)
Page: https://openlegislation.uk/control-of-electromagnetic-fields-at-work-regulations-2016/schedule/part-2/chapter-2/paragraph-5
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.