# The Control of Electromagnetic Fields at Work Regulations 2016, Paragraph 3: Notes

Extent: E+W+S

Note 2 to Table AL1 applies in relation to methods of determining exposure.
Table ELV3 – Sensory effect ELVs for exposure to electromagnetic fields from 1 to 400 Hz
Frequency range
Sensory effect ELVs – internal electric field strength in the head (E) [Vm-1]
1 ≤ f < 10 Hz
0.7/f
10 ≤ f < 25 Hz
0.07
25 ≤ f ≤ 400 Hz
0.0028 f

---
Source: https://www.legislation.gov.uk/uksi/2016/588/schedule/part/2/chapter/3/paragraph/3n4 (the official version)