# The Control of Substances Hazardous to Health Regulations 1994, Part III: CONTAINMENT MEASURES FOR INDUSTRIAL PROCESSES


Containment measures
Containment levels
2
3
4
1 Viable micro-organisms should be contained in a system which physically separates the process from the environment (closed system).
Yes
Yes
Yes
2 Exhaust gases from the closed system should be treated so as to—
Minimise release
Prevent release
Prevent release
3 Sample collection, addition of materials to a closed system and transfer of viable micro-organisms to another closed system, should be performed so as to—
Minimise release
Prevent release
Prevent release
4 Bulk culture fluids should not be removed from the closed system unless the viable micro-organisms have been—
Inactivated by validated means
Inactivated by validated chemical or physical means
Inactivated by validated chemical or physical means
5 Seals should be designed so as to—
Minimise release
Prevent release
Prevent release
6 Closed systems should be located within a controlled area—
Optional
Optional
Yes, and purpose-built
(a) biohazard signs should be posted;
Optional
Yes
Yes
(b) access should be restricted to nominated personnel only;
Optional
Yes
Yes, via air-lock
(c) personnel should wear protective clothing;
Yes, work clothing
Yes
Yes, a complete change
(d) decontamination and washing facilities should be provided for personnel;
Yes
Yes
Yes
(e) personnel should shower before leaving the controlled area;
No
Optional
Yes
(f) effluent from sinks and showers should be collected and inactivated before release;
No
Optional
Yes
(g) the controlled area should be adequately ventilated to minimise air contamination;
Optional
Optional
Yes
(h) the controlled area should be maintained at an air pressure negative to atmosphere;
No
Optional
Yes
(i) input and extract air to the controlled area should be HEPA filtered;
No
Optional
Yes
(j) the controlled area should be designed to contain spillage of the entire contents of closed system;
Optional
Yes
Yes
(k) the controlled area should be sealable to permit fumigation.
No
Optional
Yes
7 Effluent treatment before final discharge.
Inactivated by validated means
Inactivated by validated chemical or physical means
Inactivated by validated physical means

---