OpenLegislation

Schedule I1F1

England, Wales and Scotland

Original text. Later amendments are not shown.

(1)(2)
Class of casePermitted period for emission of dark smoke
1. Emissions from a forced draught oil-fired boiler furnace, or an oil engine.10 minutes in the aggregate in any period of 2 hours.
2. Emissions from a natural draught oil-fired boiler furnace (except in the cases falling within class 4 below).10 minutes in the aggregate in any period of 1 hour.
3. Emissions from a coal-fired boiler furnace:—
(a) when the vessel is not under way (except in the cases falling within class 4 below).10 minutes in the aggregate in any period of 1 hour.
(b) when the vessel is under way20 minutes in the aggregate in any period of 1 hour.
4. Emissions from a natural draught oil-fired boiler furnace or a coal-fired boiler furnace in the following cases:—
(a) a vessel with funnels shortened for the purpose of navigating the Manchester Ship Canal;
(b) a tug not under way, but preparing to get under way or supplying power to other vessels or to shore installations;20 minutes in the aggregate in any period of 1 hour.
(c) a vessel not under way but using main power for the purpose of dredging, lifting, pumping or performing some other special operation for which the vessel is designed.
5. Emissions from any other source5 minutes in the aggregate in any period of 1 hour.

Annotations

Textual amendments

F1

Regulations revoked (E.) (7.1.2015) by The Clean Air (Miscellaneous Provisions) (England) Regulations 2014 (S.I. 2014/3318), reg. 2(1), Sch. 4

Commencement

I1

Sch. in force at 1.6.1958, see reg. 1