OpenLegislation

Paragraph 3 Verification procedure

Original text. Later amendments are not shown.

The product model conforms to these Regulations if all the following conditions are satisfied in respect of the product model—

(a)

the declared values and, where applicable, the values used to calculate the declared values, are not more favourable for the manufacturer, importer, or authorised representative than the corresponding measurements carried out pursuant to paragraph 1(2)(b)(vii) or 5(2)(d) of Schedule 1A to the 2010 Regulationsf1;

(b)

the declared values meet the requirements of these Regulations, and any product information published by the manufacturer, importer or authorised representative does not contain values more favourable for the manufacturer, importer, or authorised representative than the declared values;

(c)

the determined values comply with the respective verification tolerances as given in Table 1, and for this purpose the determined values are calculated as—

(i)

the arithmetic mean over the tested units of the measured values for a given parameter; or

(ii)

the arithmetic mean of parameter values calculated from measured values;

(d)

the manufacturer, importer or authorised representative has put in place a system that complies with the requirements of regulation 10(2), (3) and (4) (software updates); and

(e)

the manufacturer, importer or authorised representative has complied with the information requirements in paragraphs 4 to 10 of Schedule 3.

Annotations

Footnotes

f1

Schedule 1A was inserted by S.I. 2019/539.