Paragraph 8 Verification tolerances
The verification tolerances set out in Table 1 must be used only by the market surveillance authority and only for the purposes of this Schedule.
The manufacturer, authorised representative or importer of a product must not use the verification tolerances—
as allowed tolerances to establish the values in the technical documentation;
in order to interpret those values with a view to achieving compliance; or
to communicate better performance.
Table 1
Verification tolerances
| Parameter | Verification tolerances |
|---|---|
| Full-load on-mode power Pon(W): | |
| Pon ≤ 2W | The determined value must not exceed the declared value by more than 0.20 W. |
| 2W < Pon ≤ 5W | The determined value must not exceed the declared value by more than 10%. |
| 5W < Pon ≤ 25W | The determined value must not exceed the declared value by more than 5%. |
| 25W < Pon ≤ 100W | The determined value must not exceed the declared value by more than 5%. |
| 100W < Pon | The determined value must not exceed the declared value by more than 2.5%. |
| Displacement factor (0-1) | The determined value must not be less than the declared value minus 0.1 units. |
| Useful luminous flux Φuse (lm) | The determined value must not be less than the declared value minus 10%. |
| No-load power Pno, Standby power Psb and Networked standby power Pnet (W) | The determined value must not exceed the declared value by more than 0.10 W. |
| CRI (0-100) | The determined value must not be less than the declared value by more than 2.0 units. |
| Flicker (Pst LM) and stroboscopic effect (SVM) | The determined value must not exceed the declared value by more than 0.1. |
| Colour consistency (MacAdam ellipse steps) | The determined number of steps must not exceed the declared number of steps. The centre of the MacAdam ellipse must be the centre declared by the supplier with a tolerance of 0.005 units. |
| Beam angle (degrees) | The determined value must not deviate from the declared value by more than 25%. |
| Control gear efficiency (0-1) | The determined value must not be less than the declared value minus 0.05 units. |
| Lumen maintenance factor (for LED and OLED) | The determined XLMF% of the sample following the test in Schedule 5 to these Regulations must not be less than XLMF, MIN%f1. |
| Survival factor (for LED and OLED) | At least 9 light sources of the test sample must be operational after completing the test in Schedule 5. |
| Excitation purity (%) | The determined value must not be less than the declared value minus 5%. |
| Correlated colour temperature (K) | The determined value must not deviate from the declared value by more than 10%. |
For light sources with linear geometry which are scalable but of very long length, such as LED strips or strings, verification testing must consider a length of 50 cm, or, if the light source is not scalable there, the nearest value to 50 cm. The light source manufacturer or importer must indicate which separate control gear is suitable for this length.
When verifying if a product model is a light source, the market surveillance authority must compare the measured values for—
chromaticity coordinates (x and y);
luminous flux;
luminous flux density; and
colour rendering index,
directly with the limit values set out in the definition for light source in regulation 2(1), without applying any tolerances.
If any of the 10 units in the sample satisfies the conditions for being a light source, the product model must be considered to be a light source.
Light sources that allow the end-user to control, manually or automatically, directly or remotely—
the luminous intensity;
colour;
correlated colour temperature;
spectrum; or
beam angle,
of the emitted light must be tested using the reference control settings.
Annotations
Footnotes
- f1
-
For the calculation of XLMF, MIN%, see the entry for “lumen maintenance factor (for LED and OLED)” in Table 5 of Schedule 3.