# The Ecodesign for Energy-Related Products and Energy Information (Lighting Products) Regulations 2021, Paragraph 1


The technical documentation referred to in regulation 12(1)(e) must include the following—
(a) the name and address of the supplier;
(b) the supplier’s model identifier;
(c) the model identifier of all equivalent models already placed on the market;
(d) identification and signature of the person empowered to bind the supplier;
(e) the declared values for the following technical parameters—
(i) useful luminous flux (Φuse) in lm;
(ii) colour rendering index (CRI);
(iii) on-mode power (Pon) in W;
(iv) beam angle in degrees for directional light sources (DLS);
(v) peak luminous intensity in cd for directional light sources (DLS);
(vi) correlated colour temperature (CCT) in K;
(vii) standby power (Psb) in W, including when it is zero;
(viii) networked standby power (Pnet) in W for connected light sources (CLS);
(ix) R9 colour rendering index value for LED and OLED light sources;
(x) survival factor for LED and OLED light sources;
(xi) lumen maintenance factor for LED and OLED light sources;
(xii) indicative lifetime L70B50 for LED and OLED light sources;
(xiii) displacement factor (cos φ1) for LED and OLED mains light sources;
(xiv) colour consistency in MacAdam ellipse steps for LED and OLED light sources;
(xv) luminance-HLLS in cd/mm2 (only for HLLS)
(xvi) flicker metric (PstLM) for LED and OLED light sources;
(xvii) stroboscopic effect metric (SVM) for LED and OLED light sources;
(xviii) excitation purity, only for CTLS, for the colours and dominant wavelength within the given range in the following table—
Colour
Dominant wavelength range
Blue
440 nm - 490 nm
Green
520 nm - 570 nm
Red
610 nm - 670 nm
(f) the calculations performed with the parameters, including the determination of the energy efficiency class;
(g) references to the designated standards applied or other standards used;
(h) testing conditions if not described fully in sub-paragraph (g);
(i) the reference control settings, and instructions on how they can be implemented, where applicable;
(j) instructions on how to remove lighting control parts and/or non-lighting parts, if any, or how to switch them off or minimise their power consumption during light source testing;
(k) specific precautions that must be taken when the model is assembled, installed, maintained or tested;
(l) where a claim of the kind referred to in paragraph 2(1) or (3) of Schedule 8 is made, the data to support such a claim.

---