  "url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021/schedule-14/paragraph-6",
  "json_url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021/schedule-14/paragraph-6.json",
  "legislation": "ukdsi/2021/9780348222920",
  "legislation_title": "The Ecodesign for Energy-Related Products and Energy Information Regulations 2021",
  "legislation_url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021",
  "path": "schedule/14/paragraph/6",
  "kind": "paragraph",
  "number": "6",
  "heading": "Compensation factors per compartment type in the calculation of SAE:",
  "text": "Table 19 sets out the compensation factors per compartment type.\nTable 19\nValues of compensation factors per compartment type\nCompartment type\nAc\nAc\nBc\nBc\nD\nManual defrost\nAuto-defrost\nFreestanding appliance\nBuilt-in appliance\n≤ 2\n3\n4\n> 4\nPantry\n1\n1\n1.02\n1\n1.02\n1.035\n1.05\nWine storage\nCellar\nFresh food\nChill\n1.03\n0-star and ice-making\n1\n1.10\n1.05\n1-star\n2-start\n3-star\nFreezer (4-star)\nFor the purposes of Table 19, the numbers in the second row of the column headed “D” are the number of external doors or compartments, whichever is lower.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/ukdsi/2021/9780348222920/schedule/14/paragraph/6",
    "retrieved_at": "2026-10-30T14:47:21.902040+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}