  "url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021/schedule-16/paragraph-3",
  "json_url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021/schedule-16/paragraph-3.json",
  "legislation": "ukdsi/2021/9780348222920",
  "legislation_title": "The Ecodesign for Energy-Related Products and Energy Information Regulations 2021",
  "legislation_url": "https://openlegislation.uk/draft-ecodesign-for-energy-related-products-and-energy-information-regulations-2021",
  "path": "schedule/16/paragraph/3",
  "kind": "paragraph",
  "number": "3",
  "heading": "Energy efficiency requirements for motors",
  "text": "(1) IE is set out in Tables 21 to 26, for different values of the motor rated output power PN at 50 Hz or 60 Hz.\n(2) IE classes are determined at rated output power (PN), rated voltage (UN), and based on 25 °C ambient reference temperature.\n(3) For 50/60 Hz motors, the requirements in Tables 21 to 26 must be met at both 50Hz and 60 Hz at the rated output power specified for 50 Hz.\n(4) For 50Hz motors the requirements in Tables 21 to 23 must be met at 50 Hz at the rated output power specified for 50 Hz.\n(5) For 60Hz motors the requirements in Tables 24 to 26 must be met at 60 Hz at the rated output power specified for 60 Hz.\n(6) Losses must be determined in accordance with Schedule 17.\nTable 21\nMinimum efficiencies (ηn) for IE2 efficiency level at 50 Hz (per cent)\nRated output power PN[kW]\n2 poles\n4 poles\n6 poles\n8 poles\n0.12\n53.6\n59.1\n50.6\n39.8\n0.18\n60.4\n64.7\n56.6\n45.9\n0.20\n61.9\n65.9\n58.2\n47.4\n0.25\n64.8\n68.5\n61.6\n50.6\n0.37\n69.5\n72.7\n67.6\n56.1\n0.40\n70.4\n73.5\n68.8\n57.2\n0.55\n74.1\n77.1\n73.1\n61.7\n0.75\n77.4\n79.6\n75.9\n66.2\n1.1\n79.6\n81.4\n78.1\n70.8\n1.5\n81.3\n82.8\n79.8\n74.1\n2.2\n83.2\n84.3\n81.8\n77.6\n3\n84.6\n85.5\n83.3\n80.0\n4\n85.8\n86.6\n84.6\n81.9\n5.5\n87.0\n87.7\n86.0\n83.8\n7.5\n88.1\n88.7\n87.2\n85.3\n11\n89.4\n89.8\n88.7\n86.9\n15\n90.3\n90.6\n89.7\n88.0\n18.5\n90.9\n91.2\n90.4\n88.6\n22\n91.3\n91.6\n90.9\n89.1\n30\n92.0\n92.3\n91.7\n89.8\n37\n92.5\n92.7\n92.2\n90.3\n45\n92.9\n93.1\n92.7\n90.7\n55\n93.2\n93.5\n93.1\n91.0\n75\n93.8\n94.0\n93.7\n91.6\n90\n94.1\n94.2\n94.0\n91.9\n110\n94.3\n94.5\n94.3\n92.3\n132\n94.6\n94.7\n94.6\n92.6\n160\n94.8\n94.9\n94.8\n93.0\n200 up to 1,000\n95.0\n95.1\n95.0\n93.5\nTable 22\nMinimum efficiencies (ηn) for IE3 efficiency level at 50 Hz (per cent)\nRated output power PN[kW]\n2 poles\n4 poles\n6 poles\n8 poles\n0.12\n60.8\n64.8\n57.7\n50.7\n0.18\n65.9\n69.9\n63.9\n58.7\n0.20\n67.2\n71.1\n65.4\n60.6\n0.25\n69.7\n73.5\n68.6\n64.1\n0.37\n73.8\n77.3\n73.5\n69.3\n0.40\n74.6\n78.0\n74.4\n70.1\n0.55\n77.8\n80.8\n77.2\n73.0\n0.75\n80.7\n82.5\n78.9\n75.0\n1.1\n82.7\n84.1\n81.0\n77.7\n1.5\n84.2\n85.3\n82.5\n79.7\n2.2\n85.9\n86.7\n84.3\n81.9\n3\n87.1\n87.7\n85.6\n83.5\n4\n88.1\n88.6\n86.8\n84.8\n5.5\n89.2\n89.6\n88.0\n86.2\n7.5\n90.1\n90.4\n89.1\n87.3\n11\n91.2\n91.4\n90.3\n88.6\n15\n91.9\n92.1\n91.2\n89.6\n18.5\n92.4\n92.6\n91.7\n90.1\n22\n92.7\n93.0\n92.2\n90.6\n30\n93.3\n93.6\n92.9\n91.3\n37\n93.7\n93.9\n93.3\n91.8\n45\n94.0\n94.2\n93.7\n92.2\n55\n94.3\n94.6\n94.1\n92.5\n75\n94.7\n95.0\n94.6\n93.1\n90\n95.0\n95.2\n94.9\n93.4\n110\n95.2\n95.4\n95.1\n93.7\n132\n95.4\n95.6\n95.4\n94.0\n160\n95.6\n95.8\n95.6\n94.3\n200 up to 1,000\n95.8\n96.0\n95.8\n94.6\nTable 23\nMinimum efficiencies (ηn) for IE4 efficiency level 50 Hz (per cent)\nRated output power PN[kW]\n2 poles\n4 poles\n6 poles\n8 poles\n0.12\n66.5\n69.8\n64.9\n62.3\n0.18\n70.8\n74.7\n70.1\n67.2\n0.20\n71.9\n75.8\n71.4\n68.4\n0.25\n74.3\n77.9\n74.1\n70.8\n0.37\n74.3\n77.9\n74.1\n70.8\n0.40\n78.9\n81.7\n78.7\n74.9\n0.55\n81.5\n83.9\n80.9\n77.0\n0.75\n83.5\n85.7\n82.7\n78.4\n1.1\n85.2\n87.2\n84.5\n80.8\n1.5\n86.5\n88.2\n85.9\n82.6\n2.2\n88.0\n89.5\n87.4\n84.5\n3\n89.1\n90.4\n88.6\n85.9\n4\n90.0\n91.1\n89.5\n87.1\n5.5\n90.9\n91.9\n90.5\n88.3\n7.5\n91.7\n92.6\n91.3\n89.3\n11\n92.6\n93.3\n92.3\n90.4\n15\n93.3\n93.9\n92.9\n91.2\n18.5\n93.7\n94.2\n93.4\n91.7\n22\n94.0\n94.5\n93.7\n92.1\n30\n94.5\n94.9\n94.2\n92.7\n37\n94.8\n95.2\n94.5\n93.1\n45\n95.0\n95.4\n94.8\n93.4\n55\n95.3\n95.7\n95.1\n93.7\n75\n95.6\n96.0\n95.4\n94.2\n90\n95.8\n96.1\n95.6\n94.4\n110\n96.0\n96.3\n95.8\n94.7\n132\n96.2\n96.4\n96.0\n94.9\n160\n96.3\n96.6\n96.2\n95.1\n200 up to 249\n96.5\n96.7\n96.3\n95.4\n250 up to 314\n96.5\n96.7\n96.5\n95.4\n315 up to 1,000\n96.5\n96.7\n96.6\n95.4\nTable 24\nMinimum efficiencies (ηn) for IE2 efficiency level at 60 Hz (per cent)\nRated output power PN [kW]\nNumber of poles\n2\n4\n6\n8\n2\n4\n6\n8\n0.12\n59.5\n64.0\n50.5\n40.0\n0.18\n64.0\n68.0\n55.0\n46.0\n0.25\n68.0\n70.0\n59.5\n52.0\n0.37\n72.0\n72.0\n64.0\n58.0\n0.55\n74.0\n75.5\n68.0\n62.0\n0.75\n75.5\n78.0\n73.0\n66.0\n1.1\n82.5\n84.0\n85.5\n75.5\n1.5\n84.0\n84.0\n86.5\n82.5\n2.2\n85.5\n87.5\n87.5\n84.0\n3.7\n87.5\n87.5\n87.5\n85.5\n5.5\n88.5\n89.5\n89.5\n85.5\n7.5\n89.5\n89.5\n89.5\n88.5\n11\n90.2\n91.0\n90.2\n88.5\n15\n90.2\n91.0\n90.2\n89.5\n18.5\n91.0\n92.4\n91.7\n89.5\n22\n91.0\n92.4\n91.7\n91.0\n30\n91.7\n93.0\n93.0\n91.0\n37\n92.4\n93.0\n93.0\n91.7\n45\n93.0\n93.6\n93.6\n91.7\n55\n93.0\n94.1\n93.6\n93.0\n75\n93.6\n94.5\n94.1\n93.0\n90\n94.5\n94.5\n94.1\n93.6\n110\n94.5\n95.0\n95.0\n93.6\n150\n95.0\n95.0\n95.0\n93.6\n185\n95.4\n95.4\n95.0\n93.6\n220\n95.4\n95.4\n95.0\n93.6\n250\n95.4\n95.4\n95.0\n93.6\n300\n95.4\n95.4\n95.0\n93.6\n335\n95.4\n95.4\n95.0\n93.6\n375 up to 1000\n95.4\n95.8\n95.0\n94.1\nTable 25\nMinimum efficiencies (ηn) for IE3 efficiency level at 60 Hz (per cent)\nRated output power PN [kW]\nNumber of poles\n2\n4\n6\n8\n2\n4\n6\n8\n0.12\n62.0\n66.0\n64.0\n59.5\n0.18\n65.6\n69.5\n67.5\n64.0\n0.25\n69.5\n73.4\n71.4\n68.0\n0.37\n73.4\n78.2\n75.3\n72.0\n0.55\n76.8\n81.1\n81.7\n74.0\n0.75\n77.0\n83.5\n82.5\n75.5\n1.1\n84.0\n86.5\n87.5\n78.5\n1.5\n85.5\n86.5\n88.5\n84.0\n2.2\n86.5\n89.5\n89.5\n85.5\n3.7\n88.5\n89.5\n89.5\n86.5\n5.5\n89.5\n91.7\n91.0\n86.5\n7.5\n90.2\n91.7\n91.0\n89.5\n11\n91.0\n92.4\n91.7\n89.5\n15\n91.0\n93.0\n91.7\n90.2\n18.5\n91.7\n93.6\n93.0\n90.2\n22\n91.7\n93.6\n93.0\n91.7\n30\n92.4\n94.1\n94.1\n91.7\n37\n93.0\n94.5\n94.1\n92.4\n45\n93.6\n95.0\n94.5\n92.4\n55\n93.6\n95.4\n94.5\n93.6\n75\n94.1\n95.4\n95.0\n93.6\n90\n95.0\n95.4\n95.0\n94.1\n110\n95.0\n95.8\n95.8\n94.1\n150\n95.4\n96.2\n95.8\n94.5\n185\n95.8\n96.2\n95.8\n95.0\n220\n95.8\n96.2\n95.8\n95.0\n250\n95.8\n96.2\n95.8\n95.0\n300\n95.8\n96.2\n95.8\n95.0\n335\n95.8\n96.2\n95.8\n95.0\n375 up to 1000\n95.8\n96.2\n95.8\n95.0\nTable 26\nMinimum efficiencies (ηn) for IE4 efficiency level at 60 Hz (per cent)\nRated output power PN [kW]\nNumber of poles\n2\n4\n6\n8\n2\n4\n6\n8\n0.12\n66.0\n70.0\n68.0\n64.0\n0.18\n70.0\n74.0\n72.0\n68.0\n0.25\n74.0\n77.0\n75.5\n72.0\n0.37\n77.0\n81.5\n78.5\n75.5\n0.55\n80.0\n84.0\n82.5\n77.0\n0.75\n82.5\n85.5\n84.0\n78.5\n1.1\n85.5\n87.5\n88.5\n81.5\n1.5\n86.5\n88.5\n89.5\n85.5\n2.2\n88.5\n91.0\n90.2\n87.5\n3.7\n89.5\n91.0\n90.2\n88.5\n5.5\n90.2\n92.4\n91.7\n88.5\n7.5\n91.7\n92.4\n92.4\n91.0\n11\n92.4\n93.6\n93.0\n91.0\n15\n92.4\n94.1\n93.0\n91.7\n18.5\n93.0\n94.5\n94.1\n91.7\n22\n93.0\n94.5\n94.1\n93.0\n30\n93.6\n95.0\n95.0\n93.0\n37\n94.1\n95.4\n95.0\n93.6\n45\n94.5\n95.4\n95.4\n93.6\n55\n94.5\n95.8\n95.4\n94.5\n75\n95.0\n96.2\n95.8\n94.5\n90\n95.4\n96.2\n95.8\n95.0\n110\n95.4\n96.2\n96.2\n95.0\n150\n95.8\n96.5\n96.2\n95.4\n185\n96.2\n96.5\n96.2\n95.4\n220\n96.2\n96.8\n96.5\n95.4\n250\n96.2\n96.8\n96.5\n95.8\n300\n96.2\n96.8\n96.5\n95.8\n335\n96.2\n96.8\n96.5\n95.8\n375 up to 1000\n96.2\n96.8\n96.5\n95.8",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/ukdsi/2021/9780348222920/schedule/16/paragraph/3",
    "retrieved_at": "2026-10-30T14:47:21.902040+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}