Paragraph 3 Measurements of on mode power demand
Measurements of the power demand (“Pmeasured”) referred to paragraph 2 of Schedule 19 must meet the following conditions.
Measurements must be made in the normal configuration.
Measurements must be—
made using a dynamic broadcast-content video signal representing typical broadcast content for electronic displays in standard dynamic range (SDR); and
the average power consumed over 10 consecutive minutes.
Measurements must be made after the electronic display has been in the off mode or, if an off-mode is not available, in standby mode, for a minimum of 1 hour immediately followed by a minimum of 1 hour in the on mode and must be completed before a maximum of 3 hours in on-mode.
The relevant video signal must be displayed during the entire on mode duration.
For electronic displays that are known to stabilise within 1 hour, the durations referred to in sub-paragraph (4) may be reduced if the resulting measurement can be shown to be within 2 per cent of the results that would otherwise be achieved using the full durations.
Where ABC is available, measurements must—
be made with ABC switched off; or