{
  "url": "https://openlegislation.uk/draft-environmental-protection-disposal-of-polychlorinated-biphenyls-and-other-dangerous-substances-amendment-regulations-northern-ireland-2025/regulation-4",
  "json_url": "https://openlegislation.uk/draft-environmental-protection-disposal-of-polychlorinated-biphenyls-and-other-dangerous-substances-amendment-regulations-northern-ireland-2025/regulation-4.json",
  "legislation": "nidsr/2025/9780338024916",
  "legislation_title": "The Environmental Protection (Disposal of Polychlorinated Biphenyls and other Dangerous Substances) (Amendment) Regulations (Northern Ireland) 2025",
  "legislation_url": "https://openlegislation.uk/draft-environmental-protection-disposal-of-polychlorinated-biphenyls-and-other-dangerous-substances-amendment-regulations-northern-ireland-2025",
  "path": "regulation/4",
  "kind": "regulation",
  "number": "4",
  "heading": "Amendment of regulation 4",
  "text": "In regulation 4—\n(1) in paragraph (1), for “, (3)”, substitute “to (3C)”;\n(2) for paragraph (3), substitute—\n“(3) Paragraph (3A) applies to a transformer in respect of which it is reasonable to assume that it contains—\n(a) 0.005% by weight, or less, of PCBs within the fluids containing PCBs; or\n(b) a total volume of 0.05dm3, or less, of fluids containing PCBs.\n(3A) A transformer to which this paragraph applies—\n(a) may be held until the end of its useful life; and\n(b) must then be decontaminated in accordance with paragraph (4)(b) to (d), or disposed of, as soon as possible.\n(3B) Paragraph (3C) applies to a transformer in respect of which it is reasonable to assume that it contains—\n(a) more than 0.005% but no more than 0.05% by weight of PCBs within the fluids containing PCBs; and\n(b) a total volume of more than 0.05dm3 of PCBs fluids containing PCBs.\n(3C) A transformer to which this paragraph applies—\n(a) may be held until the end of 31st December 2025; and\n(b) must then be decontaminated in accordance with paragraph (4)(b) to (d), or disposed of, as soon as possible.”\n(3) in paragraph (4)(a), for “less than 0.05% by weight and, if possible, to no more than 0.005% by weight” substitute “0.005% by weight, or less, or to reduce the total volume of fluids containing PCBs to 0.05dm3, or less”.\n(4) In regulation 4(8)—\n(i) in sub-paragraph (a), for “, (3)” substitute “to (3C)”;\n(ii) in sub-paragraphs (b) and (c), for “not contaminated”, in both places it occurs, substitute “relevant”;\n(iii) after paragraph (8) insert—\n“(9) In paragraph (8), “relevant equipment” means any equipment (including any capacitor or receptacle containing residual stocks) which—\n(a) contains PCBs; or\n(b) having contained PCBs, has not been decontaminated, other than one which contains a total volume of PCBs exceeding 0.05dm3.\n(10) For the purposes of paragraph (9)—\n(a) the PCB volume of a power capacitor shall be measured by reference to all of the separate elements of a combined set; and\n(b) anything of a type which may contain PCBs shall be treated as containing PCBs unless it is reasonable to assume the contrary.”",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nidsr/2025/9780338024916/regulation/4",
    "retrieved_at": "2026-10-30T15:39:57.744774+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}