# The Ecodesign for Energy-Related Products and Energy Information (Household Tumble Dryers) Regulations 2026, Paragraph 10


For a gas-fired household tumble dryer, Edry and Edry1/2 are calculated as follows—
Edry=EgdryCC+Egdry,aEdry½=Egdry½CC+Egdry½,awhere—
“Eg dry ” is the gas consumption of the eco programme at full load, in kWh and rounded to two decimal places;
“Eg dry½ ” is the gas consumption of the eco programme at partial load, in kWh and rounded to two decimal places;
“Eg dry,a ” is the auxiliary electricity consumption of the eco programme at full load, in kWh and rounded to two decimal places;
“Eg dry½,a ” is the auxiliary electricity consumption of the eco programme at partial load, in kWh and rounded to two decimal places;
“CC” is 1.9.

---
Source: https://www.legislation.gov.uk/uksi/2026/318/schedule/4/paragraph/10 (the official version)
Page: https://openlegislation.uk/ecodesign-for-energy-related-products-and-energy-information-household-tumble-dryers-regulations-2026/schedule-4/paragraph-10