  "url": "https://openlegislation.uk/ecodesign-for-energy-related-products-and-energy-information-lighting-products-regulations-2021/schedule-3/paragraph-2",
  "json_url": "https://openlegislation.uk/ecodesign-for-energy-related-products-and-energy-information-lighting-products-regulations-2021/schedule-3/paragraph-2.json",
  "legislation": "uksi/2021/1095",
  "legislation_title": "The Ecodesign for Energy-Related Products and Energy Information (Lighting Products) Regulations 2021",
  "legislation_url": "https://openlegislation.uk/ecodesign-for-energy-related-products-and-energy-information-lighting-products-regulations-2021",
  "path": "schedule/3/paragraph/2",
  "kind": "paragraph",
  "number": "2",
  "heading": "Energy efficiency requirements",
  "text": "Separate control gears\n(1) The minimum energy efficiency requirements of a separate control gear operating at full-load are the values set out in Table 4.\nTable 4\nMinimum energy efficiency for separate control gear at full-load\nDeclared output power of the control gear (Pcg) or declared power of the light source (Pls) in W, as applicable\nMinimum energy efficiency\nControl gear for HL light sources\nall wattages Pcg\n0.91\nControl gear for FL light sources\nPls ≤ 5\n5 < Pls ≤ 100\n100 < Pls\n0.71\nPls/(2 × √(Pls/36) + 38/36 × Pls+1)\n0.91\nControl gear for HID light sources\nPls ≤ 30\n30 < Pls ≤ 75\n75 < Pls ≤ 105\n105 < Pls ≤ 405\n405 < Pls\n0.78\n0.85\n0.87\n0.90\n0.92\nControl gear for LED or OLED light sources\nall wattages Pcg\nPcg 0.81/(1.09 × Pcg 0.81 + 2.10 )\n(2) For the purposes of this paragraph, the requirements of Table 4 apply to multi-wattage separate control gears in respect of the maximum declared power on which they can operate.\n(3) Where a manufacturer or importer has declared in the technical documentation that a separate control gear has been designed for no-load mode, the no-load power Pno of the control gear must not exceed 0.5W.\n(4) The standby power Psb of a separate control gear must not exceed 0.5 W.\n(5) For a connected separate control gear—\n(a) the networked standby power Pnet must not exceed 0.5 W;\n(b) the allowable values for Psb and Pnet must not be added together.\n(6) This paragraph is subject to the exemptions in paragraph 3(3) of Schedule 4.",
  "extent": "E+W+S",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. 3 para. 2 in force at 1.10.2021, see reg. 1(2)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2021/1095/schedule/3/paragraph/2",
    "retrieved_at": "2026-11-06T03:38:19.287786+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}