OpenLegislation

Regulation 5 Insertion of new regulation 5A

Original text. Later amendments are not shown.

After regulation 5 (faulty prepayment meters) insert—

“Investigation of smart meters not operating as intended

5A
(1)

This regulation applies where a customer notifies their supplier that the customer considers that their smart meter or in-home display is not operating as intended.

(2)

This regulation applies to all smart meters, including those operating as a prepayment meter.

(3)

Where this regulation applies, the requirements on the supplier set out in paragraph (4)(a), (b) and (c) are each an individual standard of performance.

(4)

Within 5 working days of receiving a notification under paragraph (1), the supplier must—

(a)

complete an initial assessment of whether the smart meter or in-home display is not operating as intended;

(b)

where appropriate, take action which will assist the supplier to identify the cause of the smart meter not operating as intended or to identify whether the in-home display is not operating as intended; and

(c)

offer to confirm, in writing, the nature and outcome of that initial assessment and the action taken.

(5)

In this regulation—

  • “customer” includes a micro-business customer, except for the purposes of paragraph (c) of the definition of “not operating as intended”; and

  • “not operating as intended” means operating in a manner where—

    1. (a)

      the supplier is not receiving remote meter readings from the smart meter, either using the means provided by a smart meter communication service or otherwise;

    2. (b)

      the customer receives an inaccurate bill as a result of the smart meter operating as described in paragraph (a);

    3. (c)

      the in-home display is not displaying accurate real-time information about the customer’s energy consumption, including tariff or expenditure information; or

    4. (d)

      in the case of a smart meter intended to operate as a prepayment meter, the customer is unable to pay remotely in advance for the consumption of gas or electricity through that meter.”.