  "heading": null,
  "text": "The adjusted volume (Vadj) of a refrigeration appliance shall be defined as:\nVadj=ΣVc×Wc×Fc×Cc Wc=(25-Tc)/20 where Tc is the design temperature in each compartment (in °C);\nwhere Vc is the net volume of a given type of compartment in the appliance and Fc is a factor which equals 1.2 for no-frost compartments and 1 for other compartments;\nCc = 1 for refrigeration appliances belonging to the normal (N) and subnormal (SN) climate classes;\nCC = Xc for refrigeration appliances belonging to the sub-tropical (ST) climate class;\nCc = Yc for refrigeration appliances belonging to the tropical (T) climate class.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1997/1941/schedule/1/paragraph/5",
    "retrieved_at": "2026-10-29T11:58:40.715628+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}