Regulation 14 Regulation 25A inserted (conversion into kWh units)
After regulation 25, insert—
“Conversion into kWh units
25A(1)Where a participant’s total energy consumption, or, if applicable, significant energy consumption, as calculated in accordance with this Chapter, is not measured in kWh, the responsible undertaking must convert the participant’s total energy consumption, or significant energy consumption into kWh.
(2)The conversion under paragraph (1) must—
(a)where reasonably practicable, be based on verifiable data, or
(b)otherwise, be based on a reasonable estimate of the amount of energy consumed in kWh.”