# The Environmental Authorisations (Scotland) Regulations 2018, Paragraph 34: Measurement of oxygen content, temperature, pressure and water vapour content of waste gases


(1) Continuous measurements carried out in accordance with paragraph 32(1) and (2) of this schedule must include the measurement of the oxygen content, temperature, pressure and water vapour content of the waste gases unless sub-paragraph (2) applies.
(2) The continuous measurement of the water vapour content of the waste gases is not necessary where the sampled waste gas is dried before the emissions are analysed.

---