# The Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations (Northern Ireland) 2017, Paragraph 10: Dust deposits


(1) Equipment and protective systems which are intended to be used in areas exposed to dust shall be so designed that deposit dust on their surfaces is not ignited.
(2) In general, dust deposits shall be limited where possible. Equipment and protective systems shall be easily cleanable.
(3) The surface temperatures of equipment parts shall be kept well below the glow temperature of the deposit dust.
(4) The thickness of deposit dust shall be taken into consideration and, if appropriate, means shall be taken to limit the temperature in order to prevent a heat build up.

---
Source: https://www.legislation.gov.uk/nisr/2017/90/schedule/1/paragraph/10 (the official version)