  "url": "https://openlegislation.uk/eu-decision-2002-735/annex/division-4/division-4.2/division-4.2.7",
  "json_url": "https://openlegislation.uk/eu-decision-2002-735/annex/division-4/division-4.2/division-4.2.7.json",
  "legislation": "eudn/2002/735",
  "legislation_title": "Commission Decision of 30 May 2002 concerning the technical specification for interoperability relating to the rolling stock subsystem of the trans-European high-speed rail system referred to in Article 6(1) of Directive 96/48/EC (notified under document number C(2002) 1952) (Text with EEA relevance) (2002/735/EC)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2002-735",
  "path": "annex/division/4/division/4.2/division/4.2.7",
  "kind": "division",
  "number": "4.2.7",
  "heading": "Passengers' emergency exits",
  "text": "(A) Arrangement: the vehicles shall have a minimum number of emergency exits on each side of the vehicle, and shall conform to the following rules:\nthe distance between each passenger seat and an emergency exit shall always be less than 16 m,\nthere shall be at least two emergency exits in each vehicle accommodating 40 passengers or less and more than two in each vehicle accommodating more than 40 passengers,\nthe dimensions through the emergency exits shall be at least 700 mm × 550 mm.\n(B) Operation: if doors cannot be opened, it is permissible to use the following as emergency exits:\nthe windows, by ejection of the window or glazing or by breaking the glass,\ncompartment doors, by rapid removal of the door or breaking the glass,\naccess doors, by ejecting them or breaking the glass.\nTrains must allow evacuation in a limited time. The dimension of doors and corridors must allow a free flow of passengers to the access doors and promote an even distribution of passengers over the doors.\n(C) Signage: emergency exits shall be clearly identified to passengers and rescue teams by means of suitable signs.\n(D) Evacuation via the doors: the interoperable high-speed trains shall be equipped with emergency devices allowing the evacuation of passengers via the access doors away from stations (emergency steps or ladders).",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2002/735/annex/division/4/division/4.2/division/4.2.7",
    "retrieved_at": "2026-11-01T15:18:29.829862+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}