The following leaching limit values apply for granular waste acceptable at landfills for hazardous waste, calculated at L/S = 2 and 10 l/kg for total release and directly expressed in mg/l for C0 (in the first eluate of percolation test at L/S = 0,1 l/kg). Granular wastes include all wastes that are not monolithic. F1The appropriate authority shall determine which of the test methods and corresponding limit values in the table should be used.

ComponentsL/S = 2 l/kgL/S = 10 l/kgC0 (percolation test)
mg/kg dry substancemg/kg dry substancemg/l
*

If the waste does not meet these values for DOC at its own pH, it may alternatively be tested at L/S = 10 l/kg and a pH of 7,5-8,0. The waste may be considered as complying with the acceptance criteria for DOC, if the result of this determination does not exceed 1 000 mg/kg. (A draft method based on prEN 14429 is available.)

**

The values for TDS can be used alternatively to the values for sulphate and chloride.

As6253
Ba10030060
Cd351,7
Cr total257015
Cu5010060
Hg0,520,3
Mo203010
Ni204012
Pb255015
Sb251
Se473
Zn9020060
Chloride17 00025 00015 000
Fluoride200500120
Sulphate25 00050 00017 000
DOC f1 4801 000320
TDS f2 70 000100 000—

F2The appropriate authority shall set criteria for monolithic waste to provide the same level of environmental protection given by the above limit values.

Annotations

Textual amendments

F1

Words in Annex section 2.4.1 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(viii)(aa); 2020 c. 1, Sch. 5 para. 1(1)

F2

Words in Annex section 2.4.1 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(viii)(bb); 2020 c. 1, Sch. 5 para. 1(1)

Footnotes

f1

*

If the waste does not meet these values for DOC at its own pH, it may alternatively be tested at L/S = 10 l/kg and a pH of 7,5-8,0. The waste may be considered as complying with the acceptance criteria for DOC, if the result of this determination does not exceed 1 000 mg/kg. (A draft method based on prEN 14429 is available.)

f2

**

The values for TDS can be used alternatively to the values for sulphate and chloride.

Notes on Division 2

Textual amendments

F1

Words in Annex section 2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(i)(aa); 2020 c. 1, Sch. 5 para. 1(1)

F2

Words in Annex section 2 substituted (31.12.2020) by The Waste (Miscellaneous Amendments) (EU Exit) Regulations 2019 (S.I. 2019/620), regs. 1(2)(b), 15(7)(d)(i)(bb); 2020 c. 1, Sch. 5 para. 1(1)