# Commission Decision of 17 January 2003 establishing the classes of reaction-to-fire performance for certain construction products (notified under document number C(2002) 4807) (Text with EEA relevance) (2003/43/EC), Annex

Extent: E+W+S+N.I.

The tables set out in this annex list construction products and/or materials which satisfy all the requirements for the performance characteristic reaction to fire without need for testing.
Table 1
Classes of reaction to fire performance for wood-based panels
Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m 3 or at least class D-s2, d2 products with minimum density 400 kg/m 3 .
A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.
Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m 3 .
Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m 3 .
Veneered, phenol- and melamine-faced panels are included for class excl. floorings.
A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m 2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.
Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.
Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.
Product
EN product standard
End use condition
Minimum density (kg/m 3 )
Minimum thickness (mm)
Class (excluding floorings)
Class (floorings)
Cement-bonded particleboard
EN 634-2
without an air gap behind the panel
1 000
10
B-s1, d0
B fl -s1
Fibreboard, hard
EN 622-2
without an air gap behind the wood-based panel
900
6
D-s2, d0
D fl -s1
Fibreboard, hard
EN 622-2
with a closed air gap not more than 22 mm behind the wood-based panel
900
6
D-s2, d2
—
Particleboard , ,
EN 312
without an air gap behind the wood-based panel
600
9
D-s2, d0
D fl -s1
Fibreboard, hard and medium , ,
EN 622-2
EN 622-3
MDF , ,
EN 622-5
MDF , ,
EN 300
Plywood , ,
EN 636
-“-
400
9
D-s2, d0
D fl -s1
Solid wood panel , ,
EN 13353
12
Flaxboard , ,
EN 15197
-“-
450
15
D-s2, d0
D fl -s1
Particleboard ,
EN 312
with a closed or an open air gap not more than 22 mm behind the wood-based panel
600
9
D-s2, d2
—
Fibreboard, hard and medium ,
EN 622-2
EN 622-3
MDF ,
EN 622-5
OSB ,
EN 300
Plywood ,
EN 636
-“-
400
9
D-s2, d2
—
Solid wood panel ,
EN 13353
12
Particleboard ,
EN 312
with a closed air gap behind the wood-based panel
600
15
D-s2, d0
D fl -s1
Fibreboard, medium ,
EN 622-3
MDF ,
EN 622-5
OSB ,
EN 300
Plywood ,
EN 636
-“-
400
15
D-s2, d1
D fl -s1
Solid wood panel ,
EN 13353
D-s2, d0
Flaxboard ,
EN 15197
-“-
450
15
D-s2, d0
D fl -s1
Particleboard ,
EN 312
with an open air gap behind the wood-based panel
600
18
D-s2, d0
D fl -s1
Fibreboard, medium ,
EN 622-3
MDF ,
EN 622-5
OSB ,
EN 300
Plywood ,
EN 636
-“-
400
18
D-s2, d0
D fl -s1
Solid wood panel ,
EN 13353
Flaxboard ,
EN 15197
-“-
450
18
D-s2, d0
D fl -s1
Particleboard
EN 312
any
600
3
E
E fl
OSB
EN 300
MDF
EN 622-5
-“-
400
3
E
E fl
250
9
E
E fl
Plywood
EN 636
-“-
400
3
E
E fl
Fibreboard, hard
EN 622-2
-“-
900
3
E
E fl
Fibreboard, medium
EN 622-3
-“-
400
9
E
E fl
Fibreboard, soft
EN 622-4
-“-
250
9
E
E fl
Table 2
Classes of reaction — to — fire performance of gypsum plasterboards
Determined according to EN ISO 536 and with no more than 5 % organic additive content.
Classes as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC.
Gypsum plasterboard
Nominal board thickness (mm)
Gypsum core
Paper grammage (g/m 2 )
Substrate
Class (excluding floorings)
Density (kg/m 3 )
Reaction to fire class
Conforming to EN 520 (except perforated boards)
≥ 6,5 < 9,5
≥ 800
A1
≤ 220
Any wood-based product with density ≥ 400 kg/m 3 or any product of at least class A2-s1, d0
A2-s1, d0
> 220 ≤ 320
B-s1, d0
≥ 9,5
≥ 600
≤ 220
Any wood-based product with density ≥ 400 kg/m 3 or any product of at least class A2-s1, d0 or any insulating product of at least class E-d2 mounted according to method 1
A2-s1, d0
> 220 ≤ 320
B-s1, d0
Table 3
Classes of reaction-to-fire performance of high-pressure decorative laminate panels
Either directly fixed (i.e. with no air gap) to a material having a reaction to fire of A2-s1, d0 or better and a density of at least 600 kg/m 3 , or mounted on a timber or metal batten support frame, with a non-ventilated (i.e. void open only at the top) air gap of at least 30 mm, the reverse face of the cavity so formed having a reaction to fire classification of A2-s1, d0 or better.
Classes as provided for in Table 1 of the Annex to Decision 2000/147/EC.
Complying with European Standard EN 438-7.
High pressure decorative laminate panels
Product detail
Minimum density (kg/m 3 )
Minimum overall thickness (mm)
Class (excluding floorings)
Interior grade non-FR Compact HPL panels
Compact HPL meeting EN 438-4 type CGS
1 350
6
D-s2, d0
Interior grade non-FR HPL composite panels with wood-based substrates
Composite panels comprising non-FR grade HPL meeting the requirements of EN 438-3, adhesively bonded to both sides of non-FR grade wood-based core of minimum thickness 12 mm complying with EN 13986, using PVAc or thermosetting adhesive at an application rate of 60 to 120 g/m 2
Wood-based core minimum density 600
HPL minimum density 1 350
12 mm wood-based core with HPL ≥ 0,5 mm bonded to both sides
D-s2, d0
Table 4
Classes of reaction-to-fire performance of structural timber products
Applies to all species covered by the product standards.
Classes as provided for in Table 1 of the Annex to Decision 2000/147/EC.
Conditioned according to EN 13238.
Product detail
Minimum mean density (kg/m 3 )
Minimum overall thickness (mm)
Class (excluding floorings)
Structural timber
Visual and machine graded structural timber with rectangular cross-sections shaped by sawing, planing or other methods or with round cross-sections
350
22
D-s2, d0

---
Source: https://www.legislation.gov.uk/eudn/2003/43/annex (the official version)