The apparatus shall be equipped with an oval-shaped probe of a maximum width of 11 millimetres containing an infra-red light-emitting photodiode (TFK type TS-US 5402) with a peak wave-length frequency of 950 nm and a matching infra-red photodetector (TRW Optron type OP 500) and having an operating distance of between 0 and 50 millimetres. The results of the measurements shall be converted into estimated lean mean content by means of a computer.

---