The headform impactors shall meet the performance requirements specified in Section 4 of Appendix I. The certified impactors may be used for a maximum of 20 impacts before re-certification. The impactors shall be re-certified if more than one year has elapsed since the previous certification or if a transducer output, in any impact, has exceeded the specified CAC.

Notes on Annex

Editorial notes

X1

Substituted by Corrigendum to Commission Decision 2004/90/EC of 23 December 2003 on the technical prescriptions for the implementation of Article 3 of Directive 2003/102/EC of the European Parliament and of the Council relating to the protection of pedestrians and other vulnerable road users before and in the event of a collision with a motor vehicle and amending Directive 70/156/EEC (Official Journal of the European Union L 31 of 4 February 2004).