OpenLegislation

Division 4.2.1

Original text. Later amendments are not shown.

When the child headform impactor is impacted by a linearly guided certification impactor, as specified in point 4.3, the peak resultant acceleration measured by one triaxial (or three uniaxial) accelerometer in the headform shall be not less than 405 g and not more than 495 g. The resultant acceleration time curve shall be uni-modal.