Division 4.2.3
When the adult headform impactor is impacted by a linearly guided certification impactor, as specified in point 4.3, the peak resultant acceleration measured by one triaxial (or three uniaxial) accelerometer in the headform shall be not less than 337,5 g and not more than 412,5 g. The resultant acceleration time curve shall be uni-modal.