# Commission Decision of 9 August 2005 establishing the classes of reaction-to-fire performance for certain construction products (notified under document number C(2005) 2925) (Text with EEA relevance) (2005/610/EC)

EU Decision 2005/610 · adopted 9 August 2005

Commission Decision of 9 August 2005 establishing the classes of reaction-to-fire performance for certain construction products (notified under document number C(2005) 2925) (Text with EEA relevance) (2005/610/EC)

## Introductory text

Commission Decision
of 9 August 2005
establishing the classes of reaction-to-fire performance for certain construction products
(notified under document number C(2005) 2925)
(Text with EEA relevance)
(2005/610/EC)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Council Directive 89/106/EEC of 21 December 1988, on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products, and in particular Article 20(2) a thereof,
Whereas:
(1)
Directive 89/106/EEC envisages that in order to take account of different levels of protection for the construction works at national, regional or local levels, it may be necessary to establish in the interpretative documents classes corresponding to the performance of products in respect of each essential requirement. Those documents have been published as the ‘Communication of the Commission with regard to the interpretative documents of Directive 89/106/EEC’.
(2)
With respect of the essential requirement of safety in the event of fire, interpretative document No 2 lists a number of interrelated measures which together define the fire safety strategy to be developed in different ways in the Member States.
(3)
Interpretative document No 2 identifies one of those measures as the limitation of the generation and spread of fire and smoke within a given area by limiting the potential of construction products to contribute to the full development of a fire.
(4)
The level of that limitation may be expressed only in terms of the different levels of reaction-to-fire performance of the products in their end-use application.
(5)
By way of harmonised solution, a system of classes was adopted in Commission Decision 2000/147/EC of 8 February 2000 implementing Council Directive 89/106/EEC as regard the classification of the reaction-to-fire performance of construction products.
(6)
In the case of certain construction products it is necessary to use the classification established in Decision 2000/147/EC.
(7)
The reaction-to-fire performance of many construction products and/or materials, within the classification provided for in Decision 2000/147/EC, is well established and sufficiently well known to fire regulators in Member States with the consequence that they do not require testing for this particular performance characteristic.
(8)
Products have been considered in relation to their end-use application, where relevant.
(9)
The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,
HAS ADOPTED THIS DECISION:

## 1 

The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘reaction to fire’ without need for further testing are set out in the Annex.

## 2 

The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.

## 3 

This Decision is addressed to the Member States.

## 

The tables set out in this Annex, list construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction to fire without need for testing.
Table 2
CLASSES OF REACTION TO FIRE PERFORMANCE OF LAMINATE FLOOR COVERINGS
Floor covering loose laid over any wood based substrate ≥ D-s2, d0, or any substrate of class A2-s1, d0.
Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
Floor covering type
Product detail
Minimum density(kg/m3)
Minimum overall thickness(mm)
ClassFloorings
Laminate floor coverings
Laminate floor coverings manufactured in accordance with EN 13329:2000.
800
6,5
EFL
Table 3
CLASSES OF REACTION TO FIRE PERFORMANCE OF RESILIENT FLOOR COVERINGS
Floor covering loose laid over any wood based substrate ≥ D-s2, d0, or any substrate of class A2-s1, d0.
Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
Floor covering type
EN product standard
Minimum mass(g/m2)
Maximum mass(g/m2)
Minimum overall thickness(mm)
ClassFloorings
Plain and decorative Linoleum
EN 548
2 300
4 900
2
EFL
Homogeneous and heterogeneous polyvinyl chloride floor coverings
EN 649
2 300
3 900
1,5
EFL
Polyvinyl chloride floor coverings with foam layer
EN 651
1 700
5 400
2
EFL
Polyvinyl chloride floor covering with cork-based backing
EN 652
3 400
3 700
3,2
EFL
Expanded (cushioned) polyvinyl chloride floor coverings
EN 653
1 000
2 800
1,1
EFL
Semi-flexible polyvinyl chloride tiles
EN 654
4 200
5 000
2
EFL
Linoleum on corkment backing
EN 687
2 900
5 300
2,5
EFL
Homogeneous and heterogeneous smooth rubber floor coverings with foam backing
EN 1816
3 400
4 300
4
EFL
Homogeneous and heterogeneous smooth rubber floor coverings
EN 1817
3 000
6 000
1,8
EFL
Homogeneous and heterogeneous relief rubber floor coverings
EN 12199
4 600
6 700
2,5
EFL
Table 4
CLASSES OF REACTION TO FIRE PERFORMANCE OF TEXTILE FLOOR COVERINGS
Floor covering glued or loose laid over a class A2-s1, d0 substrate
Class as provided for in table 2 to the Annex to Decision 2000/147/EC.
Textile floor coverings having a total mass of max 4 800 g/m2, a minimum pile thickness of 1,8 mm (ISO 1766) and:
a surface of 100 % wool,
a surface of 80 % wool or more — 20 % polyamide or less,
a surface of 80 % wool or more — 20 % polyamide/polyester or less,
a surface of 100 % polyamide,
a surface of 100 % polypropylene and if with SBR-foam backing, a total mass of > 780 g/m2. All polypropylene carpets with other foam backings are excluded.
Floor covering type
EN product standard
ClassFloorings
Non-FR machine-made wall-to-wall pile carpets and pile carpet tiles
EN 1307
EFL
Non-FR needled textile floor coverings without pile
EN 1470
EFL
Non-FR needled textile floor coverings with pile
EN 13297
EFL

---