# Commission Decision of 15 May 2007 amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance for certain construction products as regards wood-based panels (notified under document number C(2007) 2045) (Text with EEA relevance) (2007/348/EC)

EU Decision 2007/348 · adopted 15 May 2007

Commission Decision of 15 May 2007 amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance for certain construction products as regards wood-based panels (notified under document number C(2007) 2045) (Text with EEA relevance) (2007/348/EC)

## Introductory text

Commission Decision
of 15 May 2007
amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance for certain construction products as regards wood-based panels
(notified under document number C(2007) 2045)
(Text with EEA relevance)
(2007/348/EC)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products, and in particular Article 20(2) a thereof,
Whereas:
(1)
Commission Decision 2003/43/EC establishes classes of reaction-to-fire performance for certain construction products.
(2)
Decision 2003/43/EC needs to be further adapted to take account of technical progress regarding wood-based panels.
(3)
Decision 2003/43/EC should therefore be amended accordingly.
(4)
The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,
HAS ADOPTED THIS DECISION:

## 1 

The Annex to Decision 2003/43/EC is amended as set out in the Annex to this Decision.

## 2 

This Decision is addressed to the Member States.

## Signature

Done at Brussels, 15 May 2007.
For the Commission
Günter Verheugen
Vice-President

## 

In the Annex to Decision 2003/43/EC, Table 1 is replaced by the following:
‘
Table 1
Classes of reaction to fire performance for wood-based panels
Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3.
A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.
Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3.
Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3.
Veneered, phenol- and melamine-faced panels are included for class excl. floorings.
A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.
Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.
Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.
Product
EN product standard
End use condition
Minimum density(kg/m3)
Minimum thickness(mm)
Class(excluding floorings)
Class(floorings)
Cement-bonded particleboard
EN 634-2
without an air gap behind the panel
1 000
10
B-s1, d0
Bfl-s1
Fibreboard, hard
EN 622-2
without an air gap behind the wood-based panel
900
6
D-s2, d0
Dfl-s1
Fibreboard, hard
EN 622-2
with a closed air gap not more than 22 mm behind the wood-based panel
900
6
D-s2, d2
—
Particleboard,,
EN 312
without an air gap behind the wood-based panel
600
9
D-s2, d0
Dfl-s1
Fibreboard, hard and medium,,
EN 622-2
EN 622-3
MDF,,
EN 622-5
MDF,,
EN 300
Plywood,,
EN 636
-“-
400
9
D-s2, d0
Dfl-s1
Solid wood panel,,
EN 13353
12
Flaxboard,,
EN 15197
-“-
450
15
D-s2, d0
Dfl-s1
Particleboard,
EN 312
with a closed or an open air gap not more than 22 mm behind the wood-based panel
600
9
D-s2, d2
—
Fibreboard, hard and medium,
EN 622-2
EN 622-3
MDF,
EN 622-5
OSB,
EN 300
Plywood,
EN 636
-“-
400
9
D-s2, d2
—
Solid wood panel,
EN 13353
12
Particleboard,
EN 312
with a closed air gap behind the wood-based panel
600
15
D-s2, d0
Dfl-s1
Fibreboard, medium,
EN 622-3
MDF,
EN 622-5
OSB,
EN 300
Plywood,
EN 636
-“-
400
15
D-s2, d1
Dfl-s1
Solid wood panel,
EN 13353
D-s2, d0
Flaxboard,
EN 15197
-“-
450
15
D-s2, d0
Dfl-s1
Particleboard,
EN 312
with an open air gap behind the wood-based panel
600
18
D-s2, d0
Dfl-s1
Fibreboard, medium,
EN 622-3
MDF,
EN 622-5
OSB,
EN 300
Plywood,
EN 636
-“-
400
18
D-s2, d0
Dfl-s1
Solid wood panel,
EN 13353
Flaxboard,
EN 15197
-“-
450
18
D-s2, d0
Dfl-s1
Particleboard
EN 312
any
600
3
E
Efl
OSB
EN 300
MDF
EN 622-5
-“-
400
3
E
Efl
250
9
E
Efl
Plywood
EN 636
-“-
400
3
E
Efl
Fibreboard, hard
EN 622-2
-“-
900
3
E
Efl
Fibreboard, medium
EN 622-3
-“-
400
9
E
Efl
Fibreboard, soft
EN 622-4
-“-
250
9
E
Efl
’

---
Source: https://www.legislation.gov.uk/eudn/2007/348 (the official version)