  "text": "In the Annex to Decision 2003/43/EC, Table 1 is replaced by the following:\n‘\nTable 1\nClasses of reaction to fire performance for wood-based panels\nMounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3.\nA substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.\nMounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3.\nMounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3.\nVeneered, phenol- and melamine-faced panels are included for class excl. floorings.\nA vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.\nClass as provided for in Table 1 of the Annex to Decision 2000/147/EC.\nClass as provided for in Table 2 of the Annex to Decision 2000/147/EC.\nProduct\nEN product standard\nEnd use condition\nMinimum density(kg/m3)\nMinimum thickness(mm)\nClass(excluding floorings)\nClass(floorings)\nCement-bonded particleboard\nEN 634-2\nwithout an air gap behind the panel\n1 000\n10\nB-s1, d0\nBfl-s1\nFibreboard, hard\nEN 622-2\nwithout an air gap behind the wood-based panel\n900\n6\nD-s2, d0\nDfl-s1\nFibreboard, hard\nEN 622-2\nwith a closed air gap not more than 22 mm behind the wood-based panel\n900\n6\nD-s2, d2\n—\nParticleboard,,\nEN 312\nwithout an air gap behind the wood-based panel\n600\n9\nD-s2, d0\nDfl-s1\nFibreboard, hard and medium,,\nEN 622-2\nEN 622-3\nMDF,,\nEN 622-5\nMDF,,\nEN 300\nPlywood,,\nEN 636\n-“-\n400\n9\nD-s2, d0\nDfl-s1\nSolid wood panel,,\nEN 13353\n12\nFlaxboard,,\nEN 15197\n-“-\n450\n15\nD-s2, d0\nDfl-s1\nParticleboard,\nEN 312\nwith a closed or an open air gap not more than 22 mm behind the wood-based panel\n600\n9\nD-s2, d2\n—\nFibreboard, hard and medium,\nEN 622-2\nEN 622-3\nMDF,\nEN 622-5\nOSB,\nEN 300\nPlywood,\nEN 636\n-“-\n400\n9\nD-s2, d2\n—\nSolid wood panel,\nEN 13353\n12\nParticleboard,\nEN 312\nwith a closed air gap behind the wood-based panel\n600\n15\nD-s2, d0\nDfl-s1\nFibreboard, medium,\nEN 622-3\nMDF,\nEN 622-5\nOSB,\nEN 300\nPlywood,\nEN 636\n-“-\n400\n15\nD-s2, d1\nDfl-s1\nSolid wood panel,\nEN 13353\nD-s2, d0\nFlaxboard,\nEN 15197\n-“-\n450\n15\nD-s2, d0\nDfl-s1\nParticleboard,\nEN 312\nwith an open air gap behind the wood-based panel\n600\n18\nD-s2, d0\nDfl-s1\nFibreboard, medium,\nEN 622-3\nMDF,\nEN 622-5\nOSB,\nEN 300\nPlywood,\nEN 636\n-“-\n400\n18\nD-s2, d0\nDfl-s1\nSolid wood panel,\nEN 13353\nFlaxboard,\nEN 15197\n-“-\n450\n18\nD-s2, d0\nDfl-s1\nParticleboard\nEN 312\nany\n600\n3\nE\nEfl\nOSB\nEN 300\nMDF\nEN 622-5\n-“-\n400\n3\nE\nEfl\n250\n9\nE\nEfl\nPlywood\nEN 636\n-“-\n400\n3\nE\nEfl\nFibreboard, hard\nEN 622-2\n-“-\n900\n3\nE\nEfl\nFibreboard, medium\nEN 622-3\n-“-\n400\n9\nE\nEfl\nFibreboard, soft\nEN 622-4\n-“-\n250\n9\nE\nEfl\n’",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "Class as provided for in Table 1 of the Annex to Decision 2000/147/EC."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "Class as provided for in Table 2 of the Annex to Decision 2000/147/EC."
    },
    {
      "type": "footnote",
      "label": "f4",
      "text": "Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3."
    },
    {
      "type": "footnote",
      "label": "f5",
      "text": "Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3."
    },
    {
      "type": "footnote",
      "label": "f6",
      "text": "A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings."
    },
    {
      "type": "footnote",
      "label": "f7",
      "text": "Veneered, phenol- and melamine-faced panels are included for class excl. floorings."
    },
    {
      "type": "footnote",
      "label": "f8",
      "text": "Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2007/348/annex",
    "retrieved_at": "2026-11-01T15:17:11.259097+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}