# Commission Decision of 28 April 2008 amending Decision 2002/253/EC laying down case definitions for reporting communicable diseases to the Community network under Decision No 2119/98/EC of the European Parliament and of the Council (notified under document number C(2008) 1589) (Text with EEA relevance) (2008/426/EC), Division: Laboratory criteria

Extent: E+W+S+N.I.

Laboratory criteria for case confirmation
At least one of the following three:
Isolation of virus in cell culture from any clinical specimen and identification of SARS-CoV using method such as RT-PCR
Detection SARS-CoV nucleic acid in at least one of the following three:
At least two different clinical specimens (e.g. nasopharyngeal swab and stool)
The same clinical specimen collected on two or more occasions during the course of the illness (e.g. sequential nasopharyngeal aspirates)
Two different assays or repeat RT-PCR using a new RNA extract from the original clinical sample on each occasion of testing
SARS-CoV specific antibody response by one of the following two:
Seroconversion by ELISA or IFA in acute and convalescent phase serum tested in parallel
Fourfold or greater rise in antibody titre between acute and convalescent phase sera tested in parallel
Laboratory criteria for a probable case
At least one of the following two:
A single positive antibody test for SARS-CoV
A positive PCR result for SARS-CoV on a single clinical specimen and assay

---
Source: https://www.legislation.gov.uk/eudn/2008/426/annex/division/SEVERE/division/2 (the official version)