# Commission Decision of 19 December 2008 authorising methods for grading pig carcases in Denmark (notified under document number C(2008) 8498) (Only the Danish text is authentic) (2009/12/EC), Division 2

Extent: E+W+S+N.I.

The apparatus shall be equipped with nine probes of six millimetres each containing a photodiode (Siemens of the type SFH 950 LD242 II or similar) and a photodetector (Siemens of the type SFH 960 — PB 103 or similar) and having an operation distance of between one and 180 millimetres. The results of the measurements are converted into estimated lean meat content by means of a central unit.

---
Source: https://www.legislation.gov.uk/eudn/2009/12/annex/part/1/division/2 (the official version)
Page: https://openlegislation.uk/eu-decision-2009-12/annex/part-1/division-2
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.