OpenLegislation

Division 1 ENERGY STAR eligibility criteria — TEC

United Kingdom

Original text. Later amendments are not shown.

To qualify as ENERGY STAR, the TEC value obtained for imaging equipment listed in Section B, Table 1, above must not exceed the corresponding limits below.

For imaging products with a type 2 DFE, the energy consumption of the DFE, calculated as in the example below, should be excluded when comparing the product’s measured TEC value with the limits listed below. The DFE must not interfere with the ability of the imaging product to enter or exit its lower-power modes. In order to be excluded, the DFE must meet the definition in Section A.32 and be a separate processing unit that is capable of initiating activity over the network.

TEC Table 1

Product(s): Copiers, digital duplicators, fax machines, printers
Size format(s): Standard size
Marking technologies: DT, mono DS, mono EP, mono stencil, mono TT, mono high performance IJ
Monochrome product speed (ipm)Maximum TEC (kWh/week)
≤ 151 kWh
15 < x ≤ 40(0,10 kWh/ipm)x – 0,5 kWh
40 < x ≤ 82(0,35 kWh/ipm)x – 10,3 kWh
> 82(0,70 kWh/ipm)x – 39 kWh

TEC Table 2

Product(s): Copiers, digital duplicators, fax machines, printers
Size format(s): Standard size
Marking technologies: Colour DS, colour stencil, colour TT, colour EP, SI, colour high performance IJ
Monochrome product speed (ipm)Maximum TEC (kWh/week)
≤ 32(0,10 kWh/ipm)x + 2,8 kWh
32 < x ≤ 58(0,35 kWh/ipm)x – 5,2 kWh
> 58(0,70 kWh/ipm)x – 26 kWh

TEC Table 3

Product(s): MFDs
Size format(s): Standard size
Marking technologies: DT, mono DS, mono EP, mono TT, mono high performance IJ
Monochrome product speed (ipm)Maximum TEC (kWh/week)
≤ 101,5 kWh
10 < x ≤ 26(0,10 kWh/ipm)x + 0,5 kWh
26 < x ≤ 68(0,35 kWh/ipm)x – 6 kWh
> 68(0,70 kWh/ipm)x – 30 kWh

TEC Table 4

Product(s): MFDs
Size format(s): Standard size
Marking technologies: Colour DS, colour TT, colour EP, SI, colour high performance IJ
Monochrome product speed (ipm)Maximum TEC (kWh/week)
≤ 26(0,10 kWh/ipm)x + 3,5 kWh
26 < x ≤ 62(0,35 kWh/ipm)x – 3 kWh
> 62(0,70 kWh/ipm)x – 25 kWh
  1. Division