Division Test procedures
United Kingdom
Manufacturers are required to perform tests and self-certify those models that meet the ENERGY STAR guidelines.
-
In performing these tests, the partner agrees to use the applicable test procedures provided in Table 4 below.
-
The test results for qualifying products must be reported to EPA or the European Commission, as appropriate.
Additional testing and reporting requirements are provided below.
Models capable of operating at multiple voltage/frequency combinations: Manufacturers must test their products based on the market(s) in which the models will be sold and promoted as ENERGY STAR-qualified. EPA and its ENERGY STAR country partners have agreed upon a table with three voltage/frequency combinations for testing purposes. Please refer to Section D.4 for details regarding international voltage/frequency combinations for each market.
For products that are sold as ENERGY STAR in multiple international markets, and are therefore rated at multiple input voltages, the manufacturer must test and report the required power consumption or efficiency values at all relevant voltage/frequency combinations. For example, a manufacturer that ships the same model to the United States and Europe must carry out measurements, meet the specification, and report test values at both 115 volts/60 Hz and 230 volts/50 Hz in order to qualify the model as ENERGY STAR in both markets. If a model qualifies as ENERGY STAR at only one voltage/frequency combination (e.g. 115 volts/60 Hz), then it may only be qualified and promoted as ENERGY STAR in those regions that support the tested voltage/frequency combination (e.g. North America and Taiwan).
Table 4
Type 1 DFE test procedures
| Specification requirement | Test protocol | Source |
|---|---|---|
| Power supply efficiency | Internal power supply (IPS) | IPS: http://efficientpowersupplies.epri.com/ |
| External power supply (EPS) ENERGY STAR test | EPS: www.energystar.gov/powersupplies/ |