  "legislation_title": "Commission Decision of 20 April 2009 determining the Community position for a decision of the management entities under the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment on the revision of the imaging equipment specifications in Annex C, part VII, to the Agreement (2009/347/EC)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2009-347",
  "path": "annex/division/ANNEX/division/VII/division/D/division/2/division/d/division/i",
  "kind": "division",
  "number": "(i)",
  "heading": "Procedure for printers, digital duplicators and MFDs with print capability, and fax machines",
  "text": "Table 6\nTEC test procedure — Printers, digital duplicators and MFDs with print capability, and fax machines\nNotes:\n— Before beginning the test, it is helpful to check the power-management default delay times to ensure they are as-shipped, and to confirm that there is plenty of paper in the device.\n— The ‘Zero meter’ instruction may be carried out by recording the accumulated energy consumption at that time rather than literally zeroing the meter.\n— Step 1 — The off measurement period can be longer if desired, to reduce measurement error. Note that the off power is not used in the calculations.\n— Step 2 — If the unit has no ready indicator, use the time at which the power consumption level stabilises to the ready level.\n— Step 3 — After recording the Active0 time, the remainder of this job can be cancelled.\n— Step 5 — The period of 15 minutes is from job initiation. The unit must show increased energy consumption within five seconds of zeroing the meter and timer; it may be necessary to initiate printing before zeroing to assure this.\n— Step 6 — A unit that is shipped with short default delay times might begin steps 6-8 from sleep.\n— Step 9 — Units may have multiple sleep modes so that all but the last sleep mode are included in the final period.\nStep\nInitial state\nAction\nRecord (at end of step)\nPossible states measured\n1\nOff\nPlug the unit into meter. Zero the meter; wait test period (five minutes or more).\nOff energy\nOff\nTesting interval time\n2\nOff\nTurn on unit. Wait until unit indicates it is in ready mode.\n—\n—\n3\nReady\nPrint a job of at least one output image but no more than a single job per job table.\nRecord time to first sheet exiting unit. Wait until the meter shows that the unit has entered its final sleep mode.\nActive0 time\n—\n4\nSleep\nZero meter; wait one hour.\nSleep energy\nSleep\n5\nSleep\nZero meter and timer. Print one job per job table. Record time to first sheet exiting unit. Wait until timer shows that 15 minutes have elapsed.\nJob1 energy\nRecovery, active, ready, sleep\nActive1 time\n6\nReady\nRepeat step 5.\nJob2 energy\nSame as above\nActive2 time\n7\nReady\nRepeat step 5 (without active time measurement).\nJob3 energy\nSame as above\n8\nReady\nRepeat step 5 (without active time measurement).\nJob4 energy\nSame as above\n9\nReady\nZero meter and timer. Wait until meter and/or unit shows that unit has entered its final sleep mode.\nFinal time\nReady, sleep\nFinal energy\n—\nEach image is to be sent separately; they may all be part of the same document, but should not be specified in the document as multiple copies of a single original image (unless the product is a digital duplicator, as specified in Section D.2(b)).\nFor fax machines that only use one image per job, the page is to be fed into the unit’s document feeder for convenience copying, and may be placed in the document feeder before the test begins. The unit need not be connected to a telephone line unless the telephone line is necessary for performing the test. For example, if the fax machine lacks convenience copying capability, then the job performed in step 2 should be sent via phone line. On fax machines without a document feeder, the page should be placed on the platen.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2009/347/annex/division/ANNEX/division/VII/division/D/division/2/division/d/division/i",
    "retrieved_at": "2026-11-01T15:16:30.908097+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}