# Commission Decision of 16 June 2009 determining the Community position for a decision of the Management entities under the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment on the revision of the computer specifications in Annex C, part VIII, to the Agreement (Text with EEA relevance) (2009/489/EC), Division 3: Small-Scale Server Levels

Extent: E+W+S+N.I.

For the purposes of determining Idle state levels, Small-Scale Servers must qualify under Categories A or B, as defined below:
(a) Category A: All Small-Scale Servers that do not meet the definition of Category B will be considered under Category A for ENERGY STAR qualification.
(b) Category B: To qualify under Category B Small-Scale Servers must have:
processor(s) with greater than 1 physical core or greater than 1 discrete processor, and,
a minimum of 1 gigabyte of system memory,
Table 6
Small-Scale Server Efficiency Requirements
Small-Scale Server Operational Mode Power Requirements
Off Mode: ≤ 2,0 W
Idle State:
Category A: ≤ 50,0 W
Category B: ≤ 65,0 W
Capability
Additional Power Allowance
Wake On LAN (WOL)
(Applies only if computer is shipped with WOL enabled)
+ 0,7 W for Off

---