# Commission Decision of 16 June 2009 determining the Community position for a decision of the Management entities under the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficiency labelling programmes for office equipment on the revision of the computer specifications in Annex C, part VIII, to the Agreement (Text with EEA relevance) (2009/489/EC), Division IV: Maximum Power Test for Workstations

Extent: E+W+S+N.I.

The maximum power for workstations is found by the simultaneous operation of two industry standard benchmarks: Linpack to stress the core system (e.g. processor, memory, etc.) and SPECviewperf® (latest available version for the UUT) to stress the system’s GPU. Additional information on these benchmarks, including free downloads, can be found at the URLs found below:
Linpack
http://www.netlib.org/linpack/
SPECviewperf®
http://www.spec.org/benchmarks.html#gpc
This test must be repeated three times on the same UUT, and all three measurements must fall within a ± 2 % tolerance relative to the average of the three measured maximum power values.
Measurement of the maximum AC power consumption of a workstation should be conducted as follows:

---
Source: https://www.legislation.gov.uk/eudn/2009/489/annex/division/Appendix/division/IV (the official version)