  "heading": null,
  "text": "In Annex 3 to Decision 95/467/EC, in the table related to the product family ‘CHIMNEYS, FLUES AND SPECIFIC PRODUCTS’, the following entry is added:\nProducts/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).\nProducts/materials not covered by footnote *.\nProducts/materials that do not require to be tested for reaction to fire (e.g. Products/materials of Class A1 according to Commission Decision 96/603/EC, OJ L 267, 19.10.1996, p. 23).’\nSystem 1: See Directive 89/106/EEC, Annex III(2)(i), without audit-testing of samples.\nSystem 3: See Directive 89/106/EEC, Annex III(2)(ii), second possibility.\nSystem 4: See Directive 89/106/EEC, Annex III(2)(ii), third possibility.\nProduct(s)\nIntended use(s)\nLevel(s) or class(es)(Reaction to fire)\nAttestation of conformity system(s)\n‘prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys blocks, kits of free standing chimneys and attached chimneys, chimney terminals\nFor uses subject to regulations on reaction to fire\n(A1, A2, B, C)\n1\n(A1, A2, B, C), D, E\n3\n(A1 to E), F\n4",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material)."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "Products/materials not covered by footnote *."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "Products/materials that do not require to be tested for reaction to fire (e.g. Products/materials of Class A1 according to Commission Decision 96/603/EC, OJ L 267, 19.10.1996, p. 23).’"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2010/679/annex",
    "retrieved_at": "2026-11-01T15:15:58.413136+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}