# Commission Decision of 2 December 2010 establishing the classes of reaction-to-fire performance for certain construction products as regards fibrous gypsum plaster casts (notified under document C(2010) 392) (Text with EEA relevance) (2010/738/EU), Annex

Extent: E+W+S+N.I.

The table set out in this Annex lists construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction-to-fire without need for testing.
Table
Classes of reaction-to-fire performance for fibrous gypsum plaster casts reinforced with sisal fibres or jute fibres
Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.
Product
Product detail
Minimum density(kg/m3)
Class
Fibrous gypsum plaster casts
Product according to EN 13815, made by casting gypsum plaster mixed with water, reinforced by uniformly dispersed sisal or jute fibres at the rate of no more than 2,5 % by mass.
1 000
A1

---
Source: https://www.legislation.gov.uk/eudn/2010/738/annex (the official version)
Page: https://openlegislation.uk/eu-decision-2010-738/annex
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.