Division 2 Application of the formula
United Kingdom
Since the energy values of the different marine fuels involved in the formula are largely similar, it is justified to use standard values for EF0,1 % , EF and EBOG in order to simplify the application of the formula in practice. More particularly, the following standard energy values may be presumed to apply:
43,0 MJ/kg (source: DNV Petroleum Services)
40,8 MJ/kg (source: DNV Petroleum Services)
50,0 MJ/kg (ISO energy figure for methane)
The formula would accordingly be simplified as follows:
RG/F ≥ 8,6 · SF (%) – 0,816
On this basis, the only value that needs to be introduced to the formula to arrive at the required ratio between the mass of boil-off gas and marine fuel consumed (RG/F or MBOG/MF ) is the sulphur content of the marine fuel used while at berth. By means of examples, the table below indicates the minimum ratio required to meet the equivalence criteria for marine fuels with different sulphur contents.
| Sulphur content (%) | 1,0 | 1,5 | 2,0 | 2,5 | 3,0 | 3,5 |
|---|---|---|---|---|---|---|
| MBOG/MF | 7,8 | 12,1 | 16,4 | 20,7 | 25,0 | 29,3 |