OpenLegislation

Annex

United Kingdom

Original text. Later amendments are not shown.

The table set out in this Annex lists construction products and/or materials which satisfy all of the requirements for the performance characteristic ‘reaction-to-fire’ without need for testing.

Table

Classes of reaction to fire performance for decorative wallcoverings in roll and panel form

Products in accordance with EN 15102 mounted on a substrate of at least class A2-s1,d0 with a minimum thickness 12 mm and with minimum density 800 kg/m3 using starch, or starch/PVA, or cellulose/PVA adhesive applied at a maximum 200 g/m2.

Class as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC.

Productf1 Maximum mass per unit area(g/m2)Maximum thickness(mm)Classf2
Wallcoverings on cellulose fibre base1900,9D-s3,d2
Wallcoverings on cellulose fibre base and polymer coated or printed4700,7
Wallcoverings on a mixture of cellulose and polyester fibre base1600,3
Wallcoverings on a mixture of cellulose and polyester fibre base and polymer coated or printed4100,5
Wallcoverings on a polymer coated fabric base5100,7
Wallcoverings of woven textile with a backing consisting of cellulose fibre or cellulose and polyester fibre4500,8
Wallcoverings of foamed PVC with a backing consisting of cellulose fibre or cellulose and polyester fibre3101,8

Annotations

Footnotes

f1

Products in accordance with EN 15102 mounted on a substrate of at least class A2-s1,d0 with a minimum thickness 12 mm and with minimum density 800 kg/m3 using starch, or starch/PVA, or cellulose/PVA adhesive applied at a maximum 200 g/m2.

f2

Class as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC.