The Annex to Decision 2000/367/EC is amended as follows:
- (1)
in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘ceilings with no independent fire resistance’ is replaced by the following table:
‘
Applies to ceilings with no independent fire resistance Standard(s) EN 13501-2; prEN 13381-1 Classification: expressed in the same terms as the load-bearing element being protected Notes If also fulfilling the requirement with regard to the “semi-natural” fire, the symbol “sn” is added to the classification. ’
- (2)
in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘fire protective coatings, boards, renderings, claddings and screens’ is replaced by the following table:
‘
Applies to fire protective coatings, boards, renderings, claddings and screens Standard(s) EN 13501-2; prEN 13381-2 to 8 Classification: expressed in the same terms as the load-bearing element being protected Notes — ’
- (3)
in Section 4 ‘Non-load bearing elements or parts of works and products therefor’, the classification table that relates to ‘partitions (including those incorporating uninsulated portions)’ is replaced by the following table:
For cavity barriers this standard is complemented by EOTA TR 031.’
‘Applies to partitions (including partitions incorporating uninsulated portions, and cavity barriers) Standard(s) EN13501-2; EN 1364-1f1; EN 1992-1-2; EN 1993-1-2; EN 1994-1-2; EN 1995-1-2; EN 1996-1-2; EN 1999-1-2 Classification: - E 20 30 60 90 120 EI 15 20 30 45 60 90 120 180 240 EI-M 30 60 90 120 180 240 EW 20 30 60 90 120 Notes —